Physiol Rev Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Physiol. Rev. 80: 649-680, 2000;
0031-9333/00 $15.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (123)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ellis, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ellis, K. J.

Physiological Reviews, Vol. 80, No. 2, April 2000, pp. 649-680
Copyright ©2000 by the American Physiological Society

Human Body Composition: In Vivo Methods

Kenneth J. Ellis

Body Composition Laboratory, United States Department of Agriculture/ARS Children's Nutrition Research Center, Department of Pediatrics, Baylor College of Medicine and Texas Children's Hospital, Houston, Texas

I. HISTORICAL BACKGROUND AND CADAVER STUDIES
II. BODY COMPOSITION MODELS
    A.  Two-Compartment Models
    B.  Three-Compartment Models
    C.  Four-Compartment Models
    D.  Multicompartment Models
III. BODY DENSITY AND VOLUME MEASUREMENTS
    A.  Underwater Weighing
    B.  Air-Displacement Plethysmography
IV. DILUTION METHODS
    A.  Basic Principle
    B.  Total Body Water
    C.  Extracellular Water
    D.  Intracellular Water
V. BIOELECTRICAL IMPEDANCE AND CONDUCTANCE METHODS
    A.  Bioelectrical Impedance Analysis
    B.  Bioelectrical Impedance Spectroscopy
    C.  Total Body Electrical Conductivity
VI. WHOLE BODY COUNTING AND NEUTRON ACTIVATION ANALYSIS
    A.  Total Body Potassium
    B.  Neutron Activation Analysis
VII. DUAL-ENERGY X-RAY ABSORPTIOMETRY
    A.  Absorptiometric Principle
    B.  Bone Mineral Measurements
    C.  Triple-Energy X-ray Techniques
VIII. MAGNETIC RESONANCE IMAGING AND COMPUTED TOMOGRAPHY
    A.  Magnetic Resonance Imaging
    B.  Computed Tomography
IX. REFERENCE BODY COMPOSITION DATA
    A.  Infants
    B.  Children
    C.  Adults
X. MEASUREMENT OF CHANGES IN BODY COMPOSITION
XI. SUMMARY

    ABSTRACT
Top
Next
References

Ellis, Kenneth J. Human Body Composition: In Vivo Methods. Physiol. Rev. 80: 649-680, 2000.In vivo methods used to study human body composition continue to be developed, along with more advanced reference models that utilize the information obtained with these technologies. Some methods are well established, with a strong physiological basis for their measurement, whereas others are much more indirect. This review has been structured from the methodological point of view to help the reader understand what can be examined with each technique. The associations between the various in vivo methods (densitometry, dilution, bioelectrical impedance and conductance, whole body counting, neutron activation, X-ray absorptiometry, computer tomography, and magnetic resonance imaging) and the five-level multicompartment model of body composition are described, along with the limitations and advantages of each method. This review also provides an overview of the present status of this field of research in human biology, including examples of reference body composition data for infants, children, adolescents, and adults.

    I. HISTORICAL BACKGROUND AND CADAVER STUDIES
Top
Previous
Next
References

Analyses of tissue biopsies have long been a part of the practice of medicine and have contributed greatly to our fundamental knowledge of the basic physiology and metabolism of the human body. The removal of a small amount of tissue from a living subject, be it of bone, muscle, skin, fat, or visceral origin, is technically rather simple, although the procedure is not always comfortable or without risk for the subject. The performance of precise analyses of the makeup of the excised sample is possible with today's advanced technologies. However, it can be very difficult to accurately extrapolate from a single tissue sample to a complete organ, much less to the whole body; extrapolation is often the source of substantial error when estimating total body composition. Notwithstanding this limitation, most of our information about the composition of the human body has been derived in this manner and has been compiled over the years into the concept of the Reference Man (296).

Most of the studies of the human fetus and infants were conducted in the earlier part of the 1900s (105, 130, 157, 223). Direct chemical analyses of the adult whole body are much more limited. In the 1950-1970s, there were the classic works of Widdowson and co-workers (342-344), who examined both infants and adults, whereas Forbes and co-workers (116, 118, 119) reported cadaver analyses of adults only. Whole body human cadaver analyses for ages between infancy and adulthood do not exist, except for the data of one 4.5-yr-old male child, who died of tuberculous meningitis (344). More recently, Knight et al. (164) performed two adult cadaver assays, mainly focused on the determination of total body nitrogen. Complete dissections of adult human bodies also have been performed, with subsequent reports on the variations in organ weights, but not the chemical or molecular makeup of the body (5, 48, 200, 201, 214, 220). These limited data showed that the chemical composition of the body's various tissues is relatively constant among individuals, although it is not constant from birth. These data represent the direct chemical assay of the whole human body and have served as the reference base for the development of various models of human body composition. With the exception of the total body nitrogen measurement, none of the newer in vivo methodologies has been directly verified with human cadaver analysis. In the following sections of this review, the various methods currently available for assessment of body composition are described, pertinent data obtained with each method are summarized, and the relevance of each method to an integrated five-level multicompartment model is discussed. Wherever appropriate, translational relationships among the various levels will be provided for specific body composition compartments. In the final section, reference body composition data or prediction equations for the full life span are provided. This review is intended to present a status report of this field of human biology, to stimulate the interested reader to look further, and to provide the necessary references to assist in that search for knowledge.

    II. BODY COMPOSITION MODELS
Top
Previous
Next
References

There is an abundance of anthropometric data on the human body, including measurements of skinfold thickness at numerous sites, circumferences and lengths at various body parts or regions, and a number of weight-for-stature indexes. These anthropometry-based models have been developed to predict body composition for all age groups (29, 183, 186, 258). These anthropometry-based estimates of body composition are not the focus of this review, nor are methods such as ultrasound for the replacement of skinfold calipers (22, 158, 310).

A.  Two-Compartment Models

Some of the earliest information about the composition of the human body was based on chemical analyses of specific organs, and occasionally of the whole body. Development and application of the classic two-compartment (2-C) model of body composition have accelerated in recent years because of the association of excess body fat with increased risk for cardiovascular diseases. In the basic 2-C model, the body is divided into two parts. One consists of body fat, and all the remaining tissues are lumped together into the part known as the fat-free mass (FFM). The direct measurement of body fat mass has never been easy and remains a significant challenge for most body composition techniques. However, if one can determine the total FFM, then body fat can be defined indirectly as the difference between body weight and FFM. The 2-C model, which has been used in body composition research for more than 50 years, continues to serve a vital role, especially in the evaluation of newer technologies focusing on body fat assessment.

The earliest and probably the most frequently used 2-C model is based on the measurement of total body density. The most common method is hydrodensitometry or UWW, which can be traced to the pioneering work of Behnke et al. (21). It is interesting that this method primarily evolved at universities with a special focus on body fitness, often relating the measurement to human kinetics, exercise, and sports performance. At the same time, two nuclear-based methods, 40K counting and dilution with radioactive water, each of which required more sophisticated technologies than UWW, were also emerging for use with the 2-C body composition model. For the assessment of body fatness with either of these nuclear-based models, the water or potassium content of the FFM had to be measured, and their relative concentrations were assumed to be constant for all ages: 0.732 l/kg for body water (234) and 68.1 meq/kg for body potassium (117). Likewise, the density of the FFM for the 2-C model was assumed constant. (21) As long as healthy young white adults were being studied, use of these three constants was satisfactory. However, when the populations included very young or old subjects, different ethnic groups, or subjects with certain diseases, it quickly became evident that these "constants" were, at best, only average values that were often population specific.

B.  Three-Compartment Models

To reduce the limitations encountered with the 2-C models, it was only logical to expand to a three-component (3-C) configuration. This approach required that the UWW measurement include a measure of total body water, usually by the isotopic dilution method. In this 3-C model, the FFM is divided into two parts: its water content and the remaining solids (predominately protein and minerals). For this 3-C model, the density of water, fat, and body solids are used. The results obtained using this model provided some improvement over the basic 2-C model for healthy adults and older children. However, for patients with significantly depleted body protein mass and/or bone mineral mass, the estimated values for the density for the solids compartment would be incorrect; thus the final estimate of body fat mass was also inaccurate.

C.  Four-Compartment Models

To extend the basic 2-C UWW model to four compartments, one would need an accurate measure of the protein and mineral compartments, in addition to that of total body water. For this four-component (4-C) UWW model, the densities for body protein and bone mineral can be assumed as 1.34 and 3.075 kg/l, respectively (296). However, to obtain a measure of the mass of each of these body compartments, two additional measurements [neutron activation analysis for body protein and dual-energy X-ray absorptiometry (DXA) for bone mineral content] would be needed. This requirement, therefore, introduces somewhat of a dilemma with the use of the 4-C UWW model because if these two additional techniques are used, then they can be used directly to provide an accurate estimate for the body fat mass without the need for the UWW measurement. For the 4-C UWW model, the DXA value for the bone mineral compartment is relatively commonly available, whereas only eight research centers worldwide have access to the direct measurement of body protein mass. It is more common practice with the 4-C UWW model that the protein mass is assumed proportional to the bone mineral mass, independent of age and gender. If one is interested in monitoring short-term changes in fat mass, approximation of the mineral mass is acceptable because this component of the 4-C model will not change significantly for the individual even over relatively long time periods. Changes in the mass of the protein component, however, may be more of a concern if not accounted for accurately. Furthermore, it is rare that significant changes in fat mass will not be accompanied by changes in the size of the body cell mass or protein mass (56, 58, 329).

An alternate 4-C model, which does not require the UWW measurement, has also been developed. In this model, the body's FFM is divided into three basic cellular or physiological compartments: body cell mass (BCM), extracellular water fluid or water (ECW), and extracellular solids (ECS). As defined by Moore et al. (221), BCM can be based on the measurement of whole body potassium (obtained by 40K counting, described in sect. VIA) or dilution with a radioactive 42K tracer in plasma. In the determination of the ECW compartment, the dilution methods (described in sect. IV) using bromide or sulfate compounds as the tracer have been developed (76, 77, 126). The ECS compartment can be defined on the basis of total body calcium or bone mineral content (55, 58, 296). Fat-free mass is then defined as BMC + ECW + ECS, and total body fat mass as body weight minus FFM. One of the limitations with this 3-C model for FFM is that the measurement errors are cumulative and transfer directly in mass units to the final estimate for body fat mass.

D.  Multicompartment Models

It should be relatively clear to the reader at this point that with each additional measurement it may be possible to extend the number of compartments in the body composition model. Each additional measurement, however, must be compositionally independent of the previous measurements. For example, a measurement of total body chloride (TBCl) can be used instead of the bromide (Br) dilution method for the estimation of ECW volume (75, 286, 350). However, if both TBCl and Br dilution are performed at the same time, no additional information about ECW is obtained. On the other hand, if these two measurements are performed, they can provide separate confirmations for ECW volume that may not be obtained with a single measurement technique; that is, if both TBCl and Br dilution predict an abnormal state, for example, then the probability of a true abnormal condition is extremely high. If only one method is used, then there are technical or model limitations resulting in increased uncertainties associated with that method. Whenever possible, it is best to use repetitive or overlapping methods if confirmation of a normal or abnormal status is the targeted outcome.

Another example is the simultaneous measurement of body carbon and body hydrogen (by neutron activation) as assays for body fat mass and total body water, respectively (161, 178, 286). This information is a duplication of that obtained using DXA for fat mass and deuterium dilution for total body water. Alternately, the measurements of body nitrogen and body potassium can be used together to derive estimates of the skeletal muscle mass, nonmuscle lean mass, and visceral mass (33, 34, 55, 247). Techniques such as computed tomography (CT) and magnetic resonance imaging (MRI) also provide useful information about anatomical structure and can be used to monitor specific organs. Multiple slices are needed to reconstruct volumes, from which mass can be estimated if density is known. These two latter scanning techniques should not be viewed as equivalent to the basic chemical composition model, because in many diseases the apparent volume can be normal, when the chemical composition is significantly abnormal.

A survey of the literature for the last 50 years will show there was an evolutionary process from the basic 2-C models to the presently popular 4-C models of body composition. Wang et al. (335), however, had the insight to collate all of this information and to present it as a comprehensive, five-level model of body composition. This five-level model, illustrated in Figure 1, has become the standard for body composition research. The five levels of the model are as follows: elemental, molecular, cellular, tissue systems, and total body. It is interesting to note that the basic 2-C models tend to start at each end of the spectrum (for example, 40K counting is an elemental model, while body density is an example of a whole body model). As each model includes more measurements, it tends to migrate toward the cellular or physiological model. At each level (examples are presented in Table 1), equations can be used to describe that level within the total model. In addition, there are translational equations between levels, as well as hybrid or mixed level models. In general, the relationships between chemical or elemental composition (amounts of oxygen, carbon, hydrogen, nitrogen, calcium) and the molecular structure of tissues (water, protein, lipids, bone mineral) remain relatively fixed in both health and disease. Consequently, the reconstruction of body composition from the elemental level is often more reliable and minimizes the assumptions related to tissue density, hydration, and/or structure. In many ways, an accurate in vivo chemical profile of the human body can serve as a replacement for the classical wet chemistry assays used previously to study human cadavers.



View larger version (23K):
[in this window]
[in a new window]
 
Fig. 1. Basic two-compartment model and five-level multicompartment model of body composition. ECS, extracellular solids; ECF, extracellular fluid. [Modified from Wang and co-workers (332-335).]


                              
View this table:
[in this window]
[in a new window]
 
Table 1. Selected equations related to the five-level multicompartment model

    III. BODY DENSITY AND VOLUME MEASUREMENTS
Top
Previous
Next
References

A.  Underwater Weighing

Because of its early development and widespread use, the measurement of body density (Db) is often referred to as a gold standard for body composition measurements, even though it is only a 2-C model. The most commonly used method for determining body density is UWW, which requires the subject to be completely submerged in water (21). The volume of water displaced and/or the subject's weight underwater, combined with the subject's laboratory weight, are used to calculate the density (Db) of the whole body. There is little problem obtaining an accurate measure of body weight (186); the limitations and restrictions are associated with the estimates of body volume and the residual lung volume (36, 160, 291, 346).

In the classic 2-C model of body composition, body weight can be divided into its fat (ffat) and fat-free fractions (fFFM), such that 1/Db = ffat/Dfat + fFFM/DFFM, where Dfat and DFFM are the densities for the fat and FFM compartments, respectively. The assumption that the density of fat is relatively constant is reasonable (107, 200, 312). However, the heterogeneous nature of the FFM compartment (see sect. II) quickly leads one to question the validity of a constant density for this compartment. There may be individual variations related to gender and ethnicity (62, 279), as well as individual changes in density that occur with growth, sexual maturation, aging, physical activity, and a number of diseases (72, 150). Thus 3-C and 4-C models for UWW were developed that require additional measurements of the primary components of the FFM, namely, water, protein, and mineral (121, 184). The types of equations currently used to estimate body fatness, along with the body composition technique required for each of these models, are presented in Table 2.


                              
View this table:
[in this window]
[in a new window]
 
Table 2. Equations for 2-C, 3-C, and 4-C UWW models used to estimate %fat

The UWW methods were developed mainly as a means to measure body volume to assess body fatness, expressed as a percentage of body weight (%fat). Even if the body weight and volume could be measured without error, there would still be considerable uncertainty regarding the individual's %fat estimate due to normal variations in body hydration, protein, and mineral content. It has been estimated that the total cumulative error for body fatness (%fat) is on the order of 3-4% of body weight for the individual (11, 150, 290). Hence, it has been recommended that without adequate corrections for variations in the water and mineral fractions of FFM, densitometry should not be used as a criterion or reference method for heterogeneous populations (212). If one is required to make these additional measurements to correct the basic 2-C UWW estimate, it becomes controversial whether or not the UWW measurement itself is even needed. However, in cases such as pregnancy, where even minimal radiation exposure of the fetus is to be avoided, UWW should be considered.

Unfortunately, some of the technical adjustments, such as the residual lung volume correction required for all the UWW models or the body water and bone mineral measurements for the 3-C and 4-C models, are not routinely performed but are instead approximated using prediction equations. Hence, it is important to understand the limitations in accuracy imposed under these conditions on the %fat estimate. For the residual lung volume correction, the most commonly used method is oxygen dilution with a closed-circuit spirometer system. For older subjects or those with impaired pulmonary function, an open-circuit nitrogen washout procedure may be better (346). In either case, it has been shown that this correction introduces the major source of error for the %fat value. For example, an error of 100 ml for the residual lung volume translates to an uncertainty of ~1%. If residual volume is not measured, but instead estimated from equations, then the prediction error easily increases to 300-400 ml in a given subject, which produces an added 3-4% uncertainty in the %fat value. The effects of various types of measurement errors on the %fat value are given in Table 3. For example, an equivalent percentage error in residual volume or underwater weight will produce the same effect for the %fat value, whereas an error of similar magnitude for body weight will result in a much lower uncertainty. A 1°C change in the water temperature, however, introduces only a small effect on the final %fat value.


                              
View this table:
[in this window]
[in a new window]
 
Table 3. Effect of errors in residual volume, underwater weight, body weight, and water temperature when the true %fat is 15% for an individual

B.  Air-Displacement Plethysmography

In recent years, the UWW technique has begun to be replaced by air-displacement plethysmography, where the subject is immersed not in water but in a closed air-filled chamber (67, 207). The system consists of two chambers: one for the subject and the other serving as a reference volume (see Fig. 2). With the subject in one chamber, the door is closed and sealed, the pressure increased slightly, and a diaphragm, separating the two chambers, is oscillated to slightly alter the volumes. The classic relationship of pressure versus volume, at a fixed temperature, is used to solve for the volume of the subject chamber. A clear advantage of this technique compared with the UWW measurement is that the subject does not have to be submerged in water; however, all of the technical limitations related to the true volume that were noted for the UWW method remain. Multiple readings over a short period of time can be obtained, which will help to average out some of these concerns. Preliminary studies in healthy adults have shown very good agreement between the plethysmographic and UWW methods (67, 207, 208, 274). However, the accuracy of the plethysmography measurement in children has not been fully tested. These instruments presently are designed for adults and will require significant modifications and improvements if the technique is to become useful for monitoring smaller subjects, including infants.



View larger version (22K):
[in this window]
[in a new window]
 
Fig. 2. Drawing of the general configuration of an air-displacement plethysmography system. [Modified from Dempster and Aitkens (67).]

Even if all the technical limitations can be solved or corrected, we are still left with the question of the physiological accuracy of using a common FFM density among individuals (a problem common to all 2-C models). The results of anatomical studies (48), as well as studies based on chemical models (150, 185, 345), appear to indicate that the densitometric assessment for many individuals has poor accuracy; that is, the normal variation in true FFM densities within a population, compared with an average or fixed value for the same population, will ultimately determine the accuracy for that individual. The assumption of a fixed density will produce a larger error of FFM than the cumulative technical errors associated with the density measure itself. Furthermore, it is well known that the composition of the FFM changes with growth and maturation (81, 83, 95, 111-113, 140-142, 352) and during aging (55, 78, 114), as well as in many diseases (52). Hence, without additional knowledge of the composition of the FFM, the 2-C volume displacement technique may best serve to identify outliers in a population or the detection of changes in fatness in the individual over short periods of time.

    IV. DILUTION METHODS
Top
Previous
Next
References

A.  Basic Principle

The basic principle of the dilution techniques for body composition analysis is that the volume of a compartment can be defined as the ratio of the dose of a tracer, administered orally or intravenously, to its concentration in that body compartment within a short time after the dose is administered. Typically, two fluid samples (blood, saliva, or urine) are collected: one just before administration of the dose, to determine the natural background levels, and the second sample after waiting a sufficient amount of time for penetration of the tracer within the compartment of interest. If it is possible that a significant amount of the tracer might be excreted before equilibration is reached, then a cumulative urine sample must be collected to adjust the dose estimate. Alternately, multiple blood samples can be collected, and the tracer content extrapolated to time zero (77, 276). Inherent in any tracer dilution technique are four basic assumptions: 1) the tracer is distributed only in the exchangeable pool, 2) it is equally distributed within this pool, 3) it is not metabolized during the equilibration time, and 4) tracer equilibration is achieved relatively rapidly. If any of these requirements is violated, then the ratio of administered dose to fluid concentration must be adjusted. For the measurements of total body water (TBW), ECW, and intracellular water (ICW), corrections for overexpansion, nonequilibrium, and excretion of the tracers are needed (13, 126, 275). In mathematical terms, the equation that describes the dilution principle is
V=<IT>k</IT><SUB><IT>1</IT></SUB><IT>·</IT><IT>k</IT><SUB><IT>2</IT></SUB><IT>·</IT><IT>k</IT><SUB><IT>3</IT></SUB><IT>·</IT><IT>k</IT><SUB><IT>4</IT></SUB><IT>·</IT>{(<IT>D−E</IT>)<IT>/</IT>([<IT>d</IT><SUB><IT>t</IT></SUB>]<IT>−</IT>[<IT>d<SUB>0</SUB></IT>])}
where the k values are constants used to correct for differences with each of the basic model, D is the tracer dose, E is the amount excreted during the equilibration period, [dt] is the tracer concentration in the fluid sampled after time t following the administration of the dose, and [d0] is the baseline concentration before the tracer.

B.  Total Body Water

For the molecular (level 2 model) and higher levels of the multilevel model, the single molecule that constitutes the highest fraction of body mass is water. In healthy adults, TBW constitutes ~73% of the FFM or 60% of body weight for nonobese subjects (171). These fractional contents, however, are not constant across the life span (112), nor are they invariant with diseases (171, 276). At full-term birth, a healthy infant's TBW/FFM is typically 80-83% of FFM, which then decreases rapidly over the next 3-5 yr until the hydration fraction reaches that observed for adults. The change in hydration reflects a change in the ratio of water between the intracellular and extracellular compartments (112). In some clinical conditions and with certain drugs, the body can retain or lose significant amounts of water. In the healthy state, TBW tends to be well regulated, although a loss of only 15%, such as in dehydration, can be significantly life-threatening. Wang and co-workers (171) have recently reexamined the classic concept of a fixed "hydration constant" and have shown that even with significant changes in the extracellular-to-intracellular ratio, the hydration ratio (TBW/FFM) remains relatively firm. This aspect of body composition is important if one is interested in monitoring body fat mass where fat is defined as body weight minus FFM and the measurement technique is based on parameters of body water. However, if the interest is in the body cell mass (i.e., intracellular water compartment) or extracellular water space (such as in dehydration or edema), then measurement techniques that respond only to total body water are less useful, if at all.

The earliest, and still the most direct, in vivo measurement technique for TBW is that based on the dilution principle, using a tracer dose of labeled water (tritium, deuterium, or oxygen-18) and collection of two body fluid samples (blood, urine, or salvia), one predose and the second after an equilibration time of ~2-3 h. The method of analysis is dependent on the choice of tracer: radioactive beta -counting for tritium, mass spectroscopy for 18O, and infrared absorption, gas chromatography, or mass spectroscopy for deuterium. Each of these methods has received periodic reviews (275-277, 285, 311, 347). It has been shown that 2-4% of the hydrogen tracers exchange with nonaqueous hydrogen, but only ~1% of the 18O tracer (275, 276). For each of these tracers, the estimated error for a TBW measurement is typically <1 kg. For Reference Man (296), this uncertainty in TBW translates to an error of 10% (~1.4 kg) for the absolute fat mass, which translates to 2% for the %fat estimate. In general, TBW values obtained using the dilution technique are considered the reference or criterion values for comparison with alternate measurement techniques (see sect. V).

C.  Extracellular Water

The dilution techniques can be used to identify the body's exchangeable electrolyte pools, which are not necessarily the same as the total body content (139, 256, 311). The physiological importance of the exchangeable pools, however, especially at the cellular level (level 3 of multilevel model) makes them suitable for monitoring the body's extracellular and intracellular fluid compartments (28, 43, 139). To measure the volume of ECW, the basic dilution techniques are the same as those used to measure total body water, except the tracer is added to the water, and the body fluid most often sampled is plasma (28, 75, 348). The tracer most commonly used is nonradioactive Br administered orally, with a second plasma sample usually collected ~3-4 h later, although complete equilibration may not have been reached (327). The analytical Br assay in most common use is high-pressure liquid chromotography (211, 276), although a few investigators have used X-ray fluorescence, spectrophotometric, or mass spectrometry techniques (159, 255, 319).

D.  Intracellular Water

Measurement of the ICW volume can be obtained using dilution of a radioactive potassium (42K) tracer. This isotope, however, is short lived (t1//2 = 12.4 h) and is no longer routinely commercially available; hence, measurement of the exchangeable potassium pool is rarely performed. The development of the direct in vivo measurement of total body potassium (TBK) by whole body counting (79) contributed to the decline of the 42K dilution method. The most common practice in use today to estimate ICW is to orally administer a combined D2O plus Br dose, from which TBW and ECW are determined. Then, ICW is defined as their difference (ICW = TBW - ECW). Unfortunately, the measurement errors (±1 liter error for TBW and ±1.5 liter error for ECW) are cumulative, such that the uncertainty for the ICW estimate is typically ±2-3 liters. Hence, this approach should be considered adequate only for determining the mean ICW value for a population and not necessarily that of an individual. The direct measurement of TBK can normally be obtained with a considerably lower error (see sect. VI) and provides a reliable marker for ICW (42, 91, 221, 249).

    V. BIOELECTRICAL IMPEDANCE AND CONDUCTANCE METHODS
Top
Previous
Next
References

A.  Bioelectrical Impedance Analysis

The ability of tissues, and therefore the whole body, to conduct an electric current has been recognized for more than a hundred years. The aqueous tissues of the body, due to their dissolved electrolytes, are the major conductors of an electrical current, whereas body fat and bone have relatively poor conductance properties (229, 313). Although significant technical problems eliminated the viability of many electrical methods for in vivo body composition analyses, the basic principle of measuring TBW had been suggested a number of years ago (153, 230). In the 1980s, when several commercial instruments designed for bioelectrical impedance analysis (BIA) were marketed, there was a resurgence of interest in this approach for human body composition analysis. At present, it is probably the most frequently used method, due mainly to the relatively inexpensive cost of the basic instrument, its ease of operation, and its portability.

The BIA measurements are performed using four electrodes: usually two are attached at the wrist and two at the ankle. For the single-frequency measurement (typically at 50 kHz), a weak alternating current is passed through the outer pair of electrodes, while the voltage drop across the body is measured using the inner pair of electrodes from which the body's impedance is derived. To convert this information to a volume estimate, two basic assumptions are used. First, the body can be modeled as a isotropic cylindrical conductor with its length proportional to the subject's height (Ht). Second, the reactance (X) term contributing to the body's impedance (Z) is small, such that the resistance component (R) can be considered equivalent to body impedance. When these two assumptions are combined, it can be shown that the conducting volume is proportional to the term Ht2/R, called the impedance index. It should be noted, however, that the human body is not a cylindrical conductor, nor are its tissues electrically isotropic, and the reactance component of the body's impedance is nonzero (225).

At 50 kHz, the body's impedance has both resistive and reactive components. The reactive component is assumed to be related to the portion of the current that passes through cells which act like capacitors that shift the voltage and current out of phase. In electrical terms, the phase angle (phi ) is defined by the relationship: tan (phi ) = X/R, where Z2 = R2 + X2. In healthy adults, the phase angle at 50 kHz is usually in the range of 8-15° (15, 45) but varies widely at high frequencies (46). Several investigators have used the phase angle to assess body composition in various clinical conditions (241-244). In renal patients, for example, the phase angle at 50 kHz is typically <5° and has been interpreted as an indication of an expanded ECW space concurrent with a reduced ICW volume.

A number of electrical-circuit models have been used to describe the general properties of biological tissues (3, 323). One model, shown in Figure 3A, has the extracellular resistance (Re) in parallel with the intracellular resistance (Ri), while the capacitance of cells (Cm) is in series with the intracellular resistance. For this model, the impedance varies as a function of frequency, as shown in Figure 3B. At zero frequency (f = 0), the current does not penetrate the cell membranes; thus impedance is purely resistive and is equal to that of the extracellular compartment (Z0 = Re). At infinite frequencies (f = infinity ), the cells become transparent to the current, such that the impedance is equal to the resistance for a parallel circuit (Zinfinity  = ReRi/(Re Ri). Because measurements are not technically possible at zero or infinite frequency, the Z0 and Zinfinity values have to be derived mathematically by fitting the shape of the reactance versus resistance curve (60, 203). In the simplest model, Z0 and Zinfinity are assumed to be the resistance values for the extracellular and total body water space, respectively; that is, for an individual, TBW proportional to  1/Rinfinity and ECW proportional to  1/R0. To calibrate the proportionality constants for these relationships, the TBW and ECW derived by deuterium and Br dilution assays, respectively, are used as the criterion or reference values, and height is used as a measure of the conductor's length.



View larger version (22K):
[in this window]
[in a new window]
 
Fig. 3. A: electrical circuit used to describe resistance and capacitance of the whole body. B: plot of reactance versus resistance as a function of frequency. Curves in B illustrate the effects of a change in extracellular volume or electrolyte concentration. Z, impedance; fc, characteristic frequency; R0, resistance at zero frequency; Rinfinity , resistance at infinite frequency.

B.  Bioelectrical Impedance Spectroscopy

A more complex model has evolved, based on modification of a mixture theory model (135) and partitioning the whole body into a series of cylinders, each representing various body segments (203, 326). For this model, resistance and reactance measurements are made over a wide range of frequencies. One instrument based on this model is commercially available (Xitron, San Diego, CA), and the technique is often called bioelectrical impedance spectroscopy (BIS). The equations reported for the estimations of extracellular water (VECF) and intracellular water (VICF) volumes are
V<SUB>ECF</SUB>=<IT>k</IT><SUB><IT>ECF</IT></SUB><IT>/</IT>(<IT>Ht<SUP>2</SUP>·Wt<SUP>0.5</SUP>/</IT><IT>R</IT><SUB><IT>e</IT></SUB>)<SUP><IT>2/3</IT></SUP>
and
(1+V<SUB>ICF</SUB>/V<SUB>ECF</SUB>)<SUP>5/2</SUP>=[(<IT>R</IT><SUB><IT>e</IT></SUB><IT>+</IT><IT>R</IT><SUB><IT>i</IT></SUB>)<IT>/</IT><IT>R</IT><SUB><IT>i</IT></SUB>]<IT>·</IT>[<IT>1+</IT><IT>k</IT><SUB><IT>&rgr;</IT></SUB><IT>·V<SUB>ICF</SUB>/V<SUB>ECF</SUB></IT>]
where Ht is height, Wt is weight, and the R values are the resistance values for the intra- and extracellular compartments. The kECF and krho values are assumed constant and can be defined in terms of resistivity for the extracellular and intracellular tissues, body density, and body volume (65).

In the impedance locus plot shown in Figure 3B, the frequency at which reactance (X) reaches a maximum is called the characteristic frequency (fC). For the single-frequency BIA method, the 50 kHz that is used is basically assumed to be fC. In fact, fC can vary over a wide range of values for healthy individuals (60, 203, 204). It should be pointed out that the shape of the impedance locus shown in Figure 3B is not uniquely associated with the electrical-circuit model given Figure 3A as other circuits can also produce the same reactance versus resistance response (74, 120, 128, 189). These alternate electrical circuit models, however, tend to be more complicated, and the individual components do not lend themselves to a simple biological interpretation. Nevertheless, this should be kept in mind when translating the results for the simple circuit model into body composition compartments with physiological or clinical significance.

Regardless of the choice of single or multifrequency method, the resistance values obtained are considered as indirect body parameters and therefore must be calibrated with a more direct method of body composition, such as total body water, body potassium, hydrodensitometry, or DXA. Unfortunately, there are almost as many different single-frequency BIA calibration equations in the literature as there are studies, which may indicate that many of these equations are population specific, especially those that include anthropometric predictors (14, 154, 301). A secondary problem has been the use of the basic 2-C hydrodensitometry model as the reference technique without inclusion of the differences reflected by variations in the bone mineral compartment. These uncertainties with the single-frequency BIA methodology, for example, were major criticisms pointed out at the National Institutes of Health (NIH) technology conference (225); that is, these equations tend to be applicable only for classifying a population, not necessarily individuals within that population. Furthermore, many investigators found that the basic model failed; that is, the impedance index (Ht2/R) alone was not an accurate predictor and that additional anthropometric terms (i.e., weight, age, gender, race, shoulder width, girth, waist-to-hip ratio, body mass index) were included in the prediction model to reduce the standard error of the estimate. No physiological justification for the added terms was provided. Not withstanding these limitations, several of the most frequently used equations for single-frequency BIA are given in Table 4. The BIA equations have been developed for newborn infants and toddlers, children and adolescents, and all ages for adults. Baumgartner (14), for example, has compiled a detailed list. Although similar types of adjustments have been proposed for multifrequency measurements, the BIS equations do not lend themselves to easy modification. However, for calibration of the BIS measurements, a range of tissue resistivity values has been reported for different populations (96, 98, 103, 295).


                              
View this table:
[in this window]
[in a new window]
 
Table 4. Examples of BIA equations derived for the prediction of TBW, ECW, and FFM

C.  Total Body Electrical Conductivity

An alternate bioelectrical method used to measure body composition is total body electrical conductivity (TOBEC) (14, 49, 50, 108). This technique is based on the following premise. When the body is placed inside a solenoid or coil that is used to generate a time-varying electromagnetic field, eddy currents are induced in the conductive tissues in the body. These currents are opposed to the direction of flow in the external coil, which causes a perturbation of the external field, resulting in absorption of a small amount of energy (E) in the body, which is dissipated as heat. The amplitude of this effect is governed by the magnitude of the external electromagnetic field, the uniformity of the magnetic field within the coil, the conductivity of tissues, and the cross-sectional area of the body (125). If the body can be approximated by a cylinder of volume V and length L, then V proportional to  (E × L)1/2, where E is called the "TOBEC number." The conduction volume is assumed to be the body's total electrolyte volume; thus the TOBEC instrument has been calibrated with a measurement of TBW. Two commercial instruments were developed (EM-Scan, Springfield, IL), one sized for infants and the other for adults. The length of an infant's body is sufficiently short that a static measurement can be made; that is, if the outer coils are about twice the length of the body, then the infant can be placed at the center of the coils for the measurement. For adults, the whole body is scanned, and information is collected at 64 positions along the length of the body, and the output is analyzed using Fourier analysis (324). A list of TOBEC calibration equations has also been compiled by Baumgartner (14).

The basic TOBEC concept would indicate that it is relatively insensitive to shifts of fluid or electrolyte between the intracellular and extracellular compartments; hence, it has only been used to monitor TBW (49, 50). However, it was suggested that using multifrequency TOBEC coupled with Fourier analysis might provide a measure of each fluid subcompartment (125, 324), although no subsequent studies have demonstrated this application. The TOBEC measurements have been used mainly to monitor changes in body composition in women during pregnancy or lactation (37, 222), in infants (38, 64, 288), and in childhood obesity (80, 163, 254).

    VI. WHOLE BODY COUNTING AND NEUTRON ACTIVATION ANALYSIS
Top
Previous
Next
References

A.  Total Body Potassium

Whole body counters were initially built for nuclear research and weapons facilities to monitor workers for possible internal contamination as a result of man-made radioactivity. Fortunately, the number of nuclear accidents involving human exposures has been very rare; the one significant exception being the Chernobyl nuclear power incident in 1986. When monitoring workers, it was noted that a constant peak was evident (later attributed to 40K) for all workers independent of their exposure history. However, it was not until an association between 40K and FFM was reported that this method was developed for body composition use (8, 117, 173). The counting of 40K was the first true in vivo chemical assay of the human body. This isotope makes up ~0.012% of natural potassium and emits a high-energy gamma  (1.46 MeV) at the rate of ~200 dpm/g K (115, 272, 337). More than 50% of these gamma  will exit the body, which allows for external counting (156). For a 70-kg young adult male, the body content of potassium will produce ~1.5 × 104 external gamma -rays/min. The rate for a preterm infant (<2 kg body wt) is only ~500 g/min. Although this process contributes to our cumulative lifetime exposure, the health consequences of this internal dose remain unknown (179). Some have argued that the dose may not be harmful and that it may contribute to radiation hormesis (39, 187, 188).

To obtain an accurate 40K measurement in humans, there are three design considerations: 1) gamma -ray detectors with good energy resolution and high efficiency, 2) adequate shielding around the subject and detectors to reduce the terrestrial and cosmic background levels, and 3) a data acquisition system that can uniquely identify the 1.46 MeV gamma  of 40K (79, 156). Whole body counter designs range from the basic "shadow-shield" single-detector configuration to multidetector arrays housed in specially designed shielded rooms (91, 156). Counting times can range from a few minutes to an hour, depending on the reduction in background signal, counting efficiency, and size of the subject (156). The whole body counter located at Baylor College of Medicine (90, 91), for example, was designed for potassium measurements ranging from preterm infants to obese adults (see Fig. 4). The subject is in a supine position on a bed between two arrays of NaI detectors that are inside a room constructed of 20-cm-thick steel walls surrounded by 1-m-thick concrete for shielding. The 40K signal is recorded for 15 min, corrected for background, and converted to a total body potassium (TBK) value. The performance characteristics of this counter are listed in Table 5. Mannequins (also called phantoms) of various sizes are used for calibration of whole body counters (23, 138, 287) and for intercomparison among counters (106, 309).



View larger version (23K):
[in this window]
[in a new window]
 
Fig. 4. Example of a multidetector whole body counter designed to monitor body potassium in infants, children, and adults. Distance between detector arrays can be varied to maximize counting efficiency and precision. [Modified from Ellis and Shypailo (90, 91).]


                              
View this table:
[in this window]
[in a new window]
 
Table 5. Operating characteristics of the whole body counter at Baylor College of Medicine

Total body potassium has been used primarily as a marker for body cell mass as defined by Moore et al. (221). It has also been used to estimate FFM, where the TBK/FFM is based on the classical cadaver work of Forbes and co-workers (117, 118). Custom has almost enshrined these two original conversion factors, although many subsequent studies have consistently reported lower mean potassium concentrations for the FFM (see Table 6). Although the differences for the TBK/FFM are relatively small, this effect is amplified when TBK is used with the 2-C model to derive an estimate for the body's fat mass (248, 334). However, TBK serves as the best choice for normalization of metabolic parameters among subjects (246).


                              
View this table:
[in this window]
[in a new window]
 
Table 6. Estimates of the average potassium content of the fat-free mass in adult human beings

The high precision of the TBK measurement has been established, although its absolute mass accuracy is less firmly established. A direct confirmation of TBK values, for example, has not been obtained by human cadaver analyses, although it has been found to be accurate in animal measurements (unpublished data). Furthermore, when the same tracer dose of 42K was given to subjects representing a wide range of weights and heights, the calibration used for TBK correctly determined the administered dose for these subjects (51). In general, the accuracy of the whole body measurement of TBK is 1-5% for adults, decreasing slightly for the preterm infant (91).

As noted previously, TBK is considered the best body composition index for assessing body cell mass, the body's metabolically active tissues (246). The future research direction of TBK should not focus on its use with the 2-C model to estimated fat, but instead on the more advanced multicompartment models where a measure of BCM is needed. A combination of techniques, such as TBK, BIS, and DXA, should give a fuller assessment in the 3-C model of body composition. This model is the one of interest in diseases, especially those involving abnormal fluid shifts, altered endocrine function, or irregular hormonal profiles.

B.  Neutron Activation Analysis

In sections I and II, it was noted that the chemical or elemental model has been the historic reference for body composition analysis. Most of this information has been collected for tissues or organs, and the composition of the whole body has been reconstructed, such as that for Reference Man (296). A substantial paradigm change in the study of whole body composition occurred with the development of in vivo neutron activation analysis (NAA) techniques. These procedures allowed for the direct elemental analysis of the living human body (44, 53, 302). Alternate body composition techniques such as CT, MRI, DXA, electrical impedance (BIA and BIS), and tracer dilution provide information generally related to tissue density or volume, but not chemical content. For this reason, the multicompartment elemental models based on in vivo NAA have become the reference norms most often preferred for evaluation and/or calibration of the alternate techniques (331-335).

A comprehensive list of the procedures, instruments, and applications developed with the in vivo NAA techniques can be found in a series of conference publications (6, 53, 86, 99, 235, 351) and two review papers (44, 302). Combined, these publications provide a detailed historical development of the techniques, a summary of state-of-the-art facilities, and examples of some of the applications in human biology, physiology, and medicine. Today, virtually all the major elements of the body can be assayed in vivo: hydrogen, oxygen, carbon, nitrogen, calcium, phosphorus, sodium, chlorine, and potassium (via 40K counting). In addition, specialized partial-body techniques have been developed for specific elements and/or organs in the body. These elements include cadmium, mercury, iron, iodine, aluminum, boron, lithium, and silicon; the organs are kidney, liver, brain, lung, heart, and thyroid (44, 235, 302).

The basic physics of NAA can be explained simply. When an atom captures a neutron, the atom is transformed to another nuclear state of the same chemical element. This new atom can be stable or radioactive, but it will have excess energy that must be released immediately (typically <10-14 s). If the new atom is radioactive, it will decay over time with a known half-life. Thus, when the body is exposed to neutrons, gamma -rays are emitted immediately (prompt) and for some time thereafter (delayed), some of which can be detected outside the body using a monitoring instrument like that used for the 40K counting procedure (79, 91).

The number of neutron sources, the type of sources, the physical design of the irradiator, the position of the body within the neutron field, and the detection system will combine to determine the overall precision and accuracy of the analysis (79). Although each of the NAA facilities is similar, no standardization in design exists; however, recent modifications of these systems have been guided by Monte Carlo simulations (73, 298). Phantoms or mannequins that simulate of the range of human sizes and shapes are often used for calibration, and an absolute accuracy of <5% is generally achieved. A recent analysis of the theoretical basis for a prompt-gamma system (298, 299) provides a detailed description of the calibration procedures that are required. Accuracy of NAA is at least as good as that obtained using classical "wet chemistry" techniques and has been shown in animal carcass analyses to be more reliable and precise (90). Although NAA facilities have been in use for more than 30 years, a direct comparison of results between two systems has been reported only recently (194).

The NAA facilities for clinical research have been developed in a number of medical centers (17-20, 90, 195, 269, 299, 328). The two elements most frequently measured are total body calcium (TBCa), using delayed NAA, and total body nitrogen (TBN), using prompt NAA. The reported accuracy and precision are 1-2% for TBCa and 3-4% for TBN. The radiation dose for the TBN measurement is relatively low (<0.3 mSv), whereas that for the TBCa measurement is substantially higher (>3 mSv).

A major disadvantage of the NAA technique is that most of the dose is delivered to the body without the production or detection of a useful signal. To overcome this limitation, pulsed activation schemes are being developed (102, 161, 178, 215, 216, 239, 248). In this case, the detection system is gated on and off to count only at the times of highest probability for an interaction, significantly reducing the overall background signal. Some investigators have found that bismuth germanium oxide detectors offer a significant improvement over the traditional use of NaI detectors for these applications (24, 267). With these modifications, the TBN sensitivity may be improved, possibly 10-fold for the same dose. If NAA is to remain a viable option in the field of body composition research or to be considered for clinical applications, then these newer instruments must be developed further.

Probably the one major concern restraining a more general use of NAA techniques is that of the associated radiation exposure. Therefore, this issue needs to be addressed briefly. First, the environment we live in is not radiation free. The average "natural" background in the United States from all sources (cosmic, terrestrial, radon, ourselves, and man-made) is estimated at 3.6 mSv/yr (47). The doses for each of the in vivo NAA measurements of body carbon, nitrogen, and calcium are ~0.1, 0.3, and 3 mSv, respectively. For comparison, the average dose for a routine chest X-ray for an adult is typically 0.4 mSv, the range being 0.1-1.0 mSv. All clinical or diagnostic radiological procedures involve some risk, and it is essential to weigh the benefits of such measurements against its risks (25). Table 7 provides a list of life experiences with risks comparable to that for the TBN measurement (79). Even though these risks are relatively small, it is essential to continue to explore ways to reduce the doses to the lowest level possible without introducing a significant loss of precision or accuracy.


                              
View this table:
[in this window]
[in a new window]
 
Table 7. Risk associated with in vivo nitrogen measurement comparable to "every day" risks

    VII. DUAL-ENERGY X-RAY ABSORPTIOMETRY
Top
Previous
Next
References

A.  Absorptiometric Principle

When an X-ray or photon source is placed on one side of an object, the intensity of the beam on the opposite side of the object is related to its thickness, density, and chemical composition. This attenuation phenomenon is also dependent on the energy of the incident photon and is dominated by two principles at low energies: the photoelectric effect and Compton scattering (251, 257, 341). The attenuation response is nonlinear, such that for a homogeneous material, it can be described by the exponential equation I = Ioe-µT, where I is the transmitted intensity, Io is the incident intensity, T is the absorber thickness, and µ is the linear attenuation coefficient. If the thickness of the absorber is known, this relationship can also be expressed as M = (1/µm) ln(Io/I), where M is the mass of the absorber and µm is the mass attenuation coefficient (=µ/rho with rho  as the density of the absorber). If the absorber is composed of two or more materials, then the composite µm is the weight sum of the individual mass attenuation coefficients, each weighted for its fractional contribution to the total mass.

The attenuation through bone, lean tissue, and fat is different, reflecting their differences in densities and chemical composition (251). With increasing photon energy, the differences in the attenuation properties for these tissues decrease. On the basis of theoretical and experimental studies (162, 206, 227), it has been shown that if the low-energy (L) photon is ~40 keV, while the high-energy (H) photon is in the range of 70-100 keV, the mass of bone (B) and soft tissue (ST) along the beam path can be expressed as follows
M<SUB>ST</SUB>=(&mgr;<SUB>BL</SUB>LR<SUB>H</SUB>−&mgr;<SUB>BH</SUB>LR<SUB>L</SUB>)/(&mgr;<SUB>BH</SUB>&mgr;<SUB>STL</SUB>−&mgr;<SUB>STH</SUB>&mgr;<SUB>BL</SUB>)

M<SUB>B</SUB>=(&mgr;<SUB>STL</SUB>LR<SUB>H</SUB>−&mgr;<SUB>STH</SUB>LR<SUB>L</SUB>)/(&mgr;<SUB>STH</SUB>&mgr;<SUB>BL</SUB>−&mgr;<SUB>BH</SUB>&mgr;<SUB>BL</SUB>)
where LRH is ln(I/Io) at the higher energy and LRL is the same ratio at the lower energy. Thus, if the relative intensity of the transmitted beam can be measured, and the mass attenuation coefficients are accurately known, estimates of the bone mass and overlaying soft tissue mass can be calculated. This 2-C model is also used when the beam passes through body regions without bone. In this case, the appropriate attenuation coefficients are those for fat (F) and lean (S) tissues, respectively.

It should be evident that DXA is really composed of two separate sets of equations, each used to describe a 2-C model. Dual-energy X-ray absorptiometry does not provide three independent measurements, even though three body composition values [bone mineral content (BMC), lean tissue mass (LTM), and fat mass (FM)] are reported. To accomplish this feat, the manufacturers must assume that the composition of the soft tissue layer overlaying bone has the same fat-to-lean ratio as that for nonbone pixels in the same scan region (162, 206, 227, 251). Typical body images are shown in Figure 5 for the whole body, lumbar region of the spine, and the upper region of the femur. In the case of the whole body scan, ~40-45% of the pixels are classified as containing bone. The remaining pixels are used to estimate the body's fat-to-lean ratio; this value is applied to the soft tissue component in the adjacent bone pixels. Thus the relative lean-to-fat composition of the total soft tissue mass is based on sampling only one-half of the whole body. Some investigators have expressed concerns with this approach as well as those related to a significant change in the hydration of the lean tissues (267). The latter concern, however, has recently been theoretically shown not to significantly alter the estimates for the bone, lean, or fat mass (209, 210, 251, 252).



View larger version (118K):
[in this window]
[in a new window]
 
Fig. 5. Total body, spine, and hip scan images obtained using dual-energy X-ray absorptiometry.

Total body DXA measurements have not been verified by human cadaver analyses, although several studies have used animal models (31, 32, 94, 213, 240, 253, 303). The DXA-derived values for BMC, LTM, and FM have been compared with a multicompartment model based on elemental NAA and were shown to be in good agreement (148). Additional studies have compared total body BMC with TBCa, showing excellent correlation, but substantial differences in the slope of the regression equations (93, 149, 250). A recent comparison between the two NAA facilities has confirmed their agreement to within 2-3% (194); thus the majority of the differences can be attributed to the DXA technology, presumably reflecting the methods for calibration. When DXA measurements were performed on the same subjects, but with different manufacturers' instruments, there were substantial differences in the individual's body composition estimates (314-316, 318). Some of this effect can be attributed to the way in which the fitting algorithms partitioned the soft tissue mass between its lean and fat components, especially if there was an excessively abnormal fat mass. These effects were also evident when the bone mineral density (BMD) values were calculated, mainly due to a reduction in the number of pixels assigned as containing bone.

B.  Bone Mineral Measurements

The primary application of DXA has been to obtain site-specific measurements of areal BMD at the lumbar spine, femur, and forearm (193). The BMD is defined as the ratio of BMC to bone area (BA), where BA is the total area in the planar scan image for all pixels classified as containing bone. It should be noted that areal BMD is not true bone density (in g/cm3 units), which can be obtained via CT. The primary function of calculating BMD is to reduce the biological variance seen in BMC values at all ages, thus increasing the statistical power of detecting abnormal values. A number of alternate schemes have been proposed using the BMC and BA data in various combinations to derive a more accurate estimate of the true bone density (41, 233, 270, 278, 307). None of these, however, has found widespread acceptance for clinical use over the simpler BMD estimate based on the BMC/BA.

The results of a whole body DXA scan provide values for a 3-C model that is somewhat like that of the level 4 multicompartment model in that a specific tissue, namely, skeletal mass, can be examined. Dual-energy X-ray absorptiometry also provides information about the general anatomical distribution of bone within the body. The DXA-derived estimates for FM have been shown to agree well with values obtained using the 2-C models or level 1 and level 2 models (149, 150). It should be noted that although DXA provides a measure of the body's nonbone lean tissue compartment, it does not specifically measure protein mass; that is, the estimate for the lean mass obtained using DXA can vary independently of the true changes in protein mass (87, 88).

Notwithstanding these limitations, the DXA technology represents a significant advancement in measurement techniques for body composition. This procedure, which requires some cooperation by the subject, can be performed within minutes at a very low dose (usually <10 µSv), and the results can be obtained immediately. Dual-energy X-ray absorptiometry has clearly attained a dominant role in the measurement of bone loss for clinical diagnosis of osteopenia and osteoporosis (181). Newer-generation DXA instruments using only fan-beam technology have been developed but need further study to determine their accuracy for monitoring changes in body composition (12, 92, 162).

C.  Triple-Energy X-ray Techniques

Several research centers are performing feasibility studies that are focused on the development of triple-energy X-ray absorptiometry. This would be an extension of the DXA technique, but the energies must be uniquely selected. In theory, if the three energies are from the Compton scattering, photoelectric, and pair production regions, then it may be possible to obtain estimates not only for bone and fat, but also those of body water and protein mass (172, 209, 304-306).

    VIII. MAGNETIC RESONANCE IMAGING AND COMPUTED TOMOGRAPHY
Top
Previous
Next
References

A.  Magnetic Resonance Imaging

The strength of the earth's magnetic fields is very weak, such that atoms and molecules in the body are in random orientations. However, when the body is placed in a strong magnetic field (orders of magnitude greater than the earth's fields), some nuclei will attempt to align with or against the magnetic field (68). Hydrogen protons (1H), in particular, have a high affinity for alignment with the magnetic field. Other atoms found in the human body (13C, 19F, 23Na, 31P, and 39K) also display these properties, but at a substantially lower response than that for hydrogen atoms. Although only a small percentage of nuclei will be aligned, the number is sufficient to detect a change in their orientation when the magnetic field is removed or altered. The frequency at which nuclei for each element will flip or precess (relative to the direction of the constant magnetic field) is called the Larmor frequency. When radiofrequency (RF) energy, at the Larmor frequency, is applied perpendicular to the direction of the magnetic field, the nuclei will absorb this energy and change alignment. When the RF field is off, the nuclei will lose their alignment and release the stored energy. The intensity of this signal can be used to measure the number of hydrogen nuclei of the tissue. This process can be repeated at each position along the length of body until the whole body is mapped and cross-sectional MRI images at each slice can be generated. Magnetic resonance imaging is successful because hydrogen, found mainly in water, is one of the most abundant nonbound elements in the body. For other elements, their concentrations in the body are lower and the Larmor frequency changes, thus requiring an increased magnetic field strength if imaging is to be considered (302).

If the hydrogen densities of adipose and lean tissues were markedly different, then it would be possible to develop images based solely on their number of nuclei. This is not the case. Thus, to enhance the contrast between lean and fat tissues, a second feature of the nuclei, called relaxation time (T1), is used. This is the time it takes for the nuclei to release the RF-induced energy and return to a random configuration. The T1 for protons in fat is much shorter than that for protons in water. This contrast can be maximized by